We have a variety of running Ultrafast Spectroscopy measurement setups that are currently being used and are listed below.
Micro Photoluminescence System (μPL)
- Excitation: Coherent MIRA 750nm-830nm @ 120fs, 400nm (frequency doubled 800nm) @ variable excitation rate (using AOM), 725nm(PicoQuant) @ 100kHz-80MHz
- Confocal high NA (0.9, air) excitation/collection objective with Olympus IX71 confocal microscope
- Spectral detection range:
- Andor DU420 (VIS/IR) and LN cooled CCD spectrometers 400nm – 2μm (Princeton Instruments SP2300 and SP2500)
- TCSPC electronics with 40ps time resolution
- Fully compatible with liquid helium/nitrogen temperature measurements in Oxford MicrostatHiRes2
Pump/Probe Optical Spectroscopy
- 1-5kHz repetition rate, 1mJ-100fs pulse, 800nm @ pump: full spectral tunability using light conversion in TOPAS (400nm – 2.5μm)
@ probe: white light generation using Ti Saph crystal - Picosecond time resolution in reflection and transmission geometry
- Compatible with LN measurements in Janis VPF cryostat
Single particle spectroscopy
- Single QD characterization (TCSPC electronics-200ps)
- Sub micron precision motors coupled to IX71 confocal microscope for single NQD positioning
- Excitation wavelength tunability from 405nm-IR (supercontinuum generation and PicoQuant laser head) with tunable repetition rate (MIRA coupled with AOM to pump SC generation)
- High efficiency signal collection using oil/water immersion objective – Zeiss Fluar 100x NA=1.3, Olympus UPLSAPO 60XW NA=1.2
- Hanbury Brown and Twiss geometry combined with spectral detection range 400nm-2μm – LN cooled CCD spectrometers (Princeton Instruments SP2300 and SP2500)
- Compatible with liquid helium/nitrogen temperature measurements in Oxford MicrostatHiRes2
- Single DNA/molecule FRET measurement ready (calibrated with ATTO 590 dye – τ=0.15ms)
- Integrated pulse compression setup after AOM
Single particle spectroscopy
- Single QD characterization (TCSPC electronics-200ps)
- Sub micron precision motors coupled to IX71 confocal microscope for single NQD positioning
- Excitation wavelength tunability from 405nm-IR (supercontinuum generation and PicoQuant laser head) with tunable repetition rate (MIRA coupled with AOM to pump SC generation)
- High efficiency signal collection using oil/water immersion objective – Zeiss Fluar 100x NA=1.3, Olympus UPLSAPO 60XW NA=1.2
- Hanbury Brown and Twiss geometry combined with spectral detection range 400nm-2μm – LN cooled CCD spectrometers (Princeton Instruments SP2300 and SP2500)
- Compatible with liquid helium/nitrogen temperature measurements in Oxford MicrostatHiRes2
- Single DNA/molecule FRET measurement ready (calibrated with ATTO 590 dye – τ=0.15ms)
- Integrated pulse compression setup after AOM
Tsunami/SpitFire PRO
- 80MHz: 750nm-850nm @ 100fs
- 1-5kHz repetition rate, >1mJ @ 40fs pulse
- Speectral tunability: VIS/NIR/IR (2x OPAs)